Step 4) Communicate w/ Test Instruments using SCPI Commands We will use this VISA address in our LabVIEW program. You can select the instrument entry and see its VISA address within the Details to the right. Once your instrument is properly configured, it will show up under “Instruments” tab. *Please reference the IO Libraries Documentation within the IO Libraries for help getting connected.ģ.
Launch Connection Expert, which is part of the Keysight IO libraries: Start > Keysight Connection Expert. Consult your instrument’s user’s guide for additional instruction. Determine which IO interface your instrument has and connect your instrument now. Many instruments today support remote connectivity over USB, LAN, GPIB, or PCIe. Choose a physical connection that works best for you. Keysight IO Libraries are not required but can still be installed instead of or alongside NI IO Libraries. NOTE: Most LabVIEW installations will rely on NI Libraries such NI-VISA and NI-MAX. Step 3) Verify Instrument Connectivity using Keysight IO Libraries (optional) This is done by right-clicking on the desired instrument and selecting “Open VISA Test Panel”. This is useful for trying single commands, troubleshooting or performing a quick remote transaction. TIP: You can also access useful tools here to send commands and read responses from your instrument. In the example above, we have a 34972A connected via USB. Once your instrument is properly configured, it will show up under the “Devices and Interfaces” section on the left of the screen. *If required, please reference the NI MAX Documentation and/or National Instruments technical support resources for assistance getting connected to your instrument.ģ. Launch MAX, which is typically installed with NI-VISA or LabVIEW: Start > All Programs > NI MAX Consult your instrument’s user’s guide for additional information on your instruments connectivity options.Ģ.
Many instruments today support remote connectivity over USB, LAN, or GPIB. Step 2) Verify Instrument Connectivity using NI MAX (Skip to step 3 if not using NI-VISA)
#Keysight instrument drivers install#
Install Keysight IO Libraries (optional if NI-VISA is already installed).
If a demo version is required, install from ni.com/download-labview /Ģ. Download and install LabVIEW if not already installed. You will need either Keysight or NI VISA (the latter can be installed along with LabVIEW) to complete this exercise. In most cases, LabVIEW installations will rely on NI Libraries such NI-VISA and NI-MAX. #Keysight instrument drivers Pc#
NOTE: This exercise requires the PC to have VISA installed.
#Keysight instrument drivers drivers#
Communicate w/ Test Instruments using LabVIEW drivers Step1) Install Software Communicate w/ Test Instruments using SCPI Commands 5. Verify Instrument Connectivity using Keysight IO Libraries (Optional) 4. Verify Instrument Connectivity using NI Automation and Explorer (NI MAX) 3. Install required software applications Install LabVIEW Install Keysight IO Libraries Suite (optional) 2.
#Keysight instrument drivers how to#
Here is a step by step guide showing how to communicate with test instruments using LabVIEW. Automate your Keysight Test Instruments Using LabVIEW